High quality AD-155A battery backup power supply 155W 13.8V switching power supply with charger function
155W Single Output with Battery Charger (UPS Function) AD-155 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Battery low and battery polarity protection
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45KHz
2 years warranty
SPECIFICATION |
MODEL | AD-155A | AD-155B | AD-155C |
OUTPUT | | | |
Output number | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 |
DC voltage | 13.8V | 13.3V | 27.6V | 27.1V | 54V | 53.5V |
Rated Current | 10.5A | 0.5A | 5A | 0.5A | 2.7A | 0.2A |
Current Range | 0~11.5A | 0-0.5A | 0~5.5A | 0-0.5A | 0-2.7A | 0-0.5A |
Rated Power | 151.55W | 151.55W | 156.5W |
Ripple & Noise | 100mVp-p | -------- | 150mVp-p | -------- | 240mVp-p | -------- |
Voltage Adj. Range | CH1:12~14.5V | CH1:24~29V | CH1:48-58V |
Voltage Tolerance | ±2.0% | -------- | ±1.0% | -------- | ±1.0% | -------- |
Line Regulation | ±0.5% | -------- | ±0.5% | -------- | ±0.5% | -------- |
Load Regulation | ±0.5% | -------- | ±0.5% | -------- | ±0.5% | -------- |
Setup, Rise Time | 1000ms, 90ms/230VAC 2000ms, 90ms/115VAC at full load |
Hold Up Time | 24ms/230VAC 20ms/115VAC at full load |
| |
INPUT | |
Voltage Range | 88~264VAC 47~63Hz; 124~370VDC |
AC Current | 2.5A/115VAC 1.5A/230VAC |
Efficiency | 80% | 84% | 84% |
Inrush Current | Cold start 20A/115VAC 40A/230VAC |
Leakage Current | <1mA /240VAC |
| |
PROTECTION | |
Over Load | CH1:105 ~ 135% CH2:0.51 ~ 0.9A rated output power |
Protection type: AC Charging Mode: Hiccup mode, recovers automatically after fault condition is removed UPS Mode: Protected by internal fuse |
Over Voltage | CH1:15.87~18.63V | CH1:31.74~37.26V | CH1:62.1 ~ 72.9V |
Protection type:Shut down o/p voltage, re-power on to recover |
Battery Low | 10V±0.8V | 19.5V(+1.5V,-1V ) | 39V±2V |
| |
ENVIRONMENT | |
Working Temp. | -10~+60°C (Refer to “Derating Curve”) |
Working Humidity | 20~90%RH non-condensing |
Storage Temp., Humidity | -20~+85°C,10~95%RH |
Temp. Coefficient | ±0.03%/ °C(0~50°C ) |
Vibration | 10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes |
| |
SAFETY &EMC | |
Safety Standards | UL60950-1, TUV EN60950-1 |
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolation Resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25°C /70%RH |
EMC Emission | Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3 |
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A |
| |
OTHERS | |
Dimension | 199*110*50mm (L*W*H) |
Weight | 0.72Kg |
Packing | 20pcs/15.5KG |
NOTE | |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
Related Products
LRS-35 LRS-50 LRS-75 LRS-100 LRS-150 LRS-200 LRS-350
Single Output Series:
S-15 S-35 S-50 S-100 S-145 S-201 S-350
NES-15 NES-35 NES-50 NES-100 NES-150 NES-200
NES-350
Multiple Output Series:
D-60A D-120A
T-60A T-120A
Q-60B Q-120A
Dil Rail Series:
MDR-20 MDR-40 MDR-60 MDR-100
DR-15 DR-30 DR-45 DR-75 DR-120 DRP-240
Waterproof Series:
LDV-18 LDV-30 LDV-50 LDV-60 LDV-100 LDV-150 LDV-200
LDV-250
LPV-20 LPV-35 LPV-60 LPV-100
Rainproof series:
FS-100 FS-150 FS-200 FS-350 FS-400
PFC Function Series:
SP-75 SP-100 SP-150 SP-200 SP-320 SP-500
Open Frame Series:
PS-5 PS-15 PS-45 PS-65
UPS Charging Ceries:
SCP-35 SCP-50 SCP-75
AD-55A ADD-55A AD-155A ADD-155A
Dc dc converter:
SD-15C SD-25C SD-50C SD-100C SD-150C SD-200C
SD-350C
High-power series:
SCN-600 SCN-800 SCN-1000 SCN-1200 SCN-1500
SV-1000 SV-2000