China Manufacturer 75W 12V power transformer with PFC Function CE ROHS certification approved
75W Single Output with PFC Function SP-75 series
Features:
·Universal AC input/ full range
·Built-in active PFC function,PF>0.93
·100% full load burn-in test
·Protections: Short circuit/ Over load/ Over voltage
·Built-in constant current limiting circuit
·LED indicator for power on
·Fixed switching frequency at PFC: 67KHz PWM:134KHz
·2 years warranty
SPECIFICATIONS |
OUTPUT | |
Model | SP-75-5 | SP-75-7.5 | SP-75-12 | SP-75-13.5 | SP-75-15 | SP-75-24 | SP-75-27 | SP-75-48 |
DC Voltage | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |
Rated Current | 15A | 10A | 6.3A | 5.6A | 5A | 3.2A | 2.8A | 1.6A |
Current Range | 0-15A | 0-10A | 0-6.3A | 0-5.6A | 0-5A | 0-3.2A | 0-2.8A | 0-1.6A |
Rated Power | 75W | 75W | 75.6W | 75.6W | 75W | 76.8W | 75.6W | 76.8W |
Ripple & Noise | 80mVp-p | 80mVp-p | 80mVp-p | 80mVp-p | 80mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
DC Adjustment Range | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% | -5%,+10% |
Voltage Tolerance | ±2% | ±2% | ±2% | ±2% | ±2% | ±1% | ±1% | ±1% |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Setup, Rise, Hold Up Time | 800ms,60ms,36ms at full load |
| |
INPUT | |
Voltage Range | 85~264 VAC 47-63Hz;120~370VDC |
AC Current | 1.3A/115 VAC 0.7A/230VAC |
Power Factor | PF>0.93/230VAC,PF>0.96/115VAC at full load |
Efficiency | 76% | 79% | 81% | 82% | 82% | 83% | 83% | 83% |
Inrush Current | Cold start 45A/230VAC |
Leakage Current | <2mA/240VAC |
| |
PROTECTION | |
Over Load | 105%-150% rated output power |
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
Over Voltage | 115%~135% |
Protection type: Shut down o/p voltage, re-power on to recover |
Function | CN3:4~10VDC POWER OFF, <0~0.8VDC POWER ON |
| |
ENVIRONMENT | |
Working Temp. Humidity | -10℃~+60℃; 20%~90% RH non-condensing |
Storage Temp. Humidity | -20℃~+85℃; 10%~95% RH |
Temp. Coefficient | ±0.05%/℃(0~50℃) |
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
| |
SAFETY | |
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG: 0.5KVAC |
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/25℃/70% RH |
| |
STANDARD | |
Safety Standard | Design refer to UL60950-1,TUV EN60950 |
EMC Standard | Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,light industry level, criteria A |
| |
OTHERS | |
Dimension | 179*99*33mm(L*W*H) |
Weight | 0.58Kg/pc;20pcs/12kg/0.64CUFT |
| |
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |